SITRANS LH100
Contact
SITRANS LH100 is a submersible hydrostatic pressure sensor for level measurement in tanks, basins, channels, and dams. It offers various measuring ranges and includes an optional explosion-proof version for hazardous environments.
Categories: Pressure, Single-range transmitters
Brand: Siemens
Key Features
-
Compact design for easy installation
-
Simple mounting without the need for complex structural support
-
High accuracy with an error margin of only ±0.3% of full scale
-
High protection rating IP68, ensuring stable performance in continuous submersion
-
Supplied with accessories including cable junction box and mounting clamp for flexible installation
Typical Applications
-
Marine industry: level monitoring in storage tanks and bilges
-
Water supply and wastewater treatment
-
Level measurement in wells, open tanks, and non-pressurized vessels
-
Outdoor and continuously wet environments
Design and Construction
-
Uses a ceramic sensor with integrated Wheatstone bridge
-
Measuring element and electronics fully enclosed in a stainless steel housing
-
Vented cable with integrated moisture filter to equalize atmospheric pressure and prevent condensation
-
Sensor membrane protected by an impact- and debris-resistant cover
-
Equipped with full-range temperature compensation to maintain measurement accuracy under varying environmental conditions
Mode of Operation
-
The sensing membrane located at the bottom of the device is exposed to the hydrostatic pressure of the liquid column
-
Hydrostatic pressure, proportional to liquid depth, is transmitted to the Wheatstone bridge within the sensor
-
Output voltage is processed by internal electronics and converted into a 4–20 mA signal
-
The vented cable enables atmospheric pressure equalization, ensuring accurate readings
-
Grounding/noise shielding is connected to the device enclosure for improved operational stability and safety
Technical Specifications – SITRANS LH100 (Submersible Sensor)
Category | Details |
Mode of Operation | |
Measuring principle | Piezo-resistive |
Input | |
Measured variable | Hydrostatic level |
Measuring ranges | 0 … 3 mH₂O (0 … 9 ftH₂O) 0 … 4 mH₂O (0 … 12 ftH₂O) 0 … 5 mH₂O (0 … 15 ftH₂O) 0 … 6 mH₂O (0 … 18 ftH₂O) 0 … 10 mH₂O (0 … 30 ftH₂O) 0 … 20 mH₂O (0 … 60 ftH₂O) 0 … 0.3 bar 0 … 0.4 bar 0 … 0.5 bar 0 … 0.6 bar 0 … 1 bar 0 … 2 bar |
Max. permissible operating pressure | 1.5 bar (21.8 psi) → for 0–3 to 0–6 mH₂O 3.0 bar (43.5 psi) → for 0–10 mH₂O 5.0 bar (72.5 psi) → for 0–20 mH₂O and higher bar ranges |
Output | |
Output signal | 4 … 20 mA |
Measuring Accuracy | (According to IEC 62828-1) |
For 0 … 3 mH₂O (0 … 9 ftH₂O or 0 … 0.3 bar) | – Typical: 0.5% of full-scale – Max: 1.0% of full-scale |
For all other ranges | – Typical: 0.3% of full-scale – Max: 0.6% of full-scale |
Effect of Ambient Temperature | |
0 … 3 mH₂O (9 ftH₂O or 0.3 bar) | 0.45% / 10 K of range end value |
4 … 6 mH₂O (12 … 18 ftH₂O or 0.4 … 0.6 bar) | 0.45% / 10 K of range end value |
> 6 mH₂O (>18 ftH₂O or >0.6 bar) | 0.3% / 10 K of range end value |
Long-Term Stability | |
3 mH₂O (0.3 bar) | 0.4% / year |
4 … 6 mH₂O (0.4 … 0.6 bar) | 0.25% / year |
> 6 mH₂O (>0.6 bar) | 0.2% / year |
Operating Conditions | |
Process temperature | –10 … +80 °C (14 … 176 °F) |
Storage temperature | –40 … +80 °C (–40 … +176 °F) |
Degree of protection | IP68 |
Structural Design | |
Weight (transmitter only) | ≈ 0.2 kg (≈ 0.44 lb) |
Cable | – Max length: 100 m (330 ft) – Weight: 0.025 kg/m (≈ 0.015 lb/ft) |
Electrical connection | Cable with 3 conductors, vent pipe, integrated humidity filter |
Materials | |
Diaphragm | Al₂O₃ ceramic, 96% |
Enclosure | Stainless steel, 1.4404 / 316L |
Gasket | – FPM (standard) – EPDM (optional) |
Connecting cable | – PE-HD (standard) – PE-LD (with EPDM, for drinking water) |
Auxiliary Power | |
Voltage UB | 10 … 33 V DC 10 … 30 V DC (with intrinsic safety) |
Certificates and Approvals | |
Drinking water approval (ACS) | ACS 15 ACC NY 360 |
EAC | № TC RU C-DE.ГБ05.В.00732 |
UL (USA & Canada) | 2014-11-17 – E344532 |
PED 2014/68/EU | Not subject to pressure directive |
Explosion Protection | |
Intrinsic safety “i” | – IECEx SEV 14.0003 – SEV 14 ATEX 0109 – II 1 G Ex ia IIC T4 Ga – EAC Ex: TC RU C-DE.AA87.B.00324 |
Cable Box (Optional Accessory)
Category | Details |
Area of application | For connecting the transmitter cable |
Weight | 0.2 kg (0.44 lb) |
Electrical connection | 2 × 3-way (28–18 AWG) |
Cable entry | 2 × Pg 9 |
Material | Polycarbonate |
Venting | Atmospheric pressure vent |
Protection class | IP65 (IEC 60529) |
Anchoring Clamp (Optional Accessory)
Category | Details |
Area of application | For mounting the transmitter |
Weight | 0.16 kg (0.35 lb) |
Material | Zinc-plated steel, polyamide |